Anytime CT3 CGM-Yuwell-POCTech

We value your privacy. When visiting our website, please agree to the use of all cookies. For more information on how we process your personal data, please visit: Privacy Policy

  • c3_banner_pc.webp

    Anytime CT3 CGM

    A factory-calibrated CGM system with a reusable transmitter and up to 14 days of sensor wear.*

Why Anytime CT3

Designed to make everyday glucose monitoring practical and cost-effective through frequent readings, connected data sharing and a long-lasting reusable transmitter.

  • 0c_icon5.svg

    Up to 14 Days of Wear

  • 0c_icon7.svg

    Readings Every 3 Minutes

  • c1_bc_01.svg

    Factory Calibration

  • c1_bc_03.svg

    Customizable Glucose Alerts

  • c1_bc_06.svg

    Cost-Effective Monitoring with a Transmitter Reusable for 2 Years

  • c1_bc_05.svg

    Real-Time Data Sharing with Caregivers and Healthcare Professionals

c3_img_01.webp

Beyond Data,Toward Better Health

Your continuous glucose data is more than just numbers-it’s a window into your body.

See how food,exercise,and sleep truly affect you.Track trends,spot patterns,and generate shareablereports-all from the app.

Simple,smart,and always with you.

  • pg01.jpg
  • pg02.jpg
  • pg03.jpg

Anytime 3 Specifications

  • c_icon1.svg
    MARD Value
    9.07% ¹
  • c_icon2.svg
    Intended User
    ≥18 years old
  • c_icon3.svg
    Sensor Wear Duration
    14 days
  • c_icon4.svg
    Reading Interval
    3 mins
  • c_icon5.svg
    Warm-Up Time
    60 mins
  • c_icon6.svg
    Sensor Weight
    6.5 g
  • c_icon8.svg
    Water Resistance
    IP 58
  • c1_bc_07.svg
    Bluetooth Transmission Range
    6m
  • c_icon4.svg
    Shelf Life
    Sensor: 1 year; Transmitter: 2 years

*Up to 14 days of sensor wear and glucose readings every 3 minutes. Product features, indications and availability may vary by configuration and country. Please refer to the applicable Instructions for Use.

†The sensor is single-use; only the transmitter is reusable. Follow the Instructions for Use for transmitter care, reuse limits and replacement.

‡Routine calibration is not required during normal use. A blood glucose check may still be required if symptoms do not match sensor readings or when instructed by the system or Instructions for Use.

§Automatic data transfer and alerts require a compatible smartphone, supported app and operating system, Bluetooth connectivity and appropriate settings, including enabled notifications for alerts. Data sharing requires user authorization, compatible devices/services and internet connectivity. Data may be delayed or interrupted. Alerts and shared data are not intended for emergency monitoring.

¶Clinical performance results apply to the specific CT3 configuration, study population and calibration conditions evaluated. 

1 Reference: Zhou L, et al. A Prospective Multicenter Assessment of the Accuracy and Safety of the Yuwell CT3 Real-Time Continuous Glucose Monitoring System in Patients With Diabetes Over 14 Days. J Diabetes. 2026 Jul;18(7):e70246.     doi: 10.1111/1753-0407.70246

The Anytime CT3 CGM System must be used in accordance with the applicable Instructions for Use. Do not ignore symptoms or delay medical care based on sensor glucose readings. If symptoms do not match readings, perform a blood glucose check as instructed. Make treatment decisions only in accordance with the approved product labeling and guidance from your healthcare professional.